Licensed and Bonded:
CA LIC #979723, B & C2
A small fast-growing winery constructed a new brewing and storage facility. The building is metal construction and insulated with closed cell spray foam insulation.
Intumescent coating was applied to the foam above 7 ft on the walls and the overhead roof. After foam installation, the owner installed steel panels to cover the foam at the ground floor level.
Thickness: Overhead roof: 3 inches, side-walls: 2 inches.
Product: Bayseal CC
Intumescent Coatiung: DC315